Skip to content

Sustainability

A media archive is read occasionally and kept for decades, so it should not draw power all the time. Meta Martis stores archives on drives that power down when idle, using about 210 watts per petabyte, including the server.

A quiet storage room with its racks powered down and a plant by the door

Power use

Meta8 OnPrem runs on disk archive hardware that stops each hard drive whenever it is not reading or writing, so most of the archive sits switched off.

Power draw About 210 watts per petabyte, including the server, with 22 to 24 TB drives. That is under 2 amps at 120 volts, or about 1,840 kWh per petabyte per year. Larger drives lower the figure.
Drive running time A drive can spin for as little as 50 hours a year, depending on how often its files are read. The rest of the time it is stopped.
Wake-up A stopped drive takes about 60 seconds to spin up. That is why access to any file begins within 60 seconds.
Density Up to 60 drives in a 4U chassis with a built-in server.
Scale One system holds over 200 PB. Larger archives run on several systems side by side, added as the archive grows.
Sizing circuits Size circuits to the equipment’s rated peak draw, not the yearly average, because drives draw more while spinning up. We give your electrician the rated figures for your configuration during the Free Archive Assessment.

Figures are published by Disk Archive Corporation, which makes the hardware.

See Meta8 OnPrem, Meta8 Private Cloud and About Meta Martis.

The Free Archive Assessment includes storage options for your library.

Request a Free Archive Assessmentinfo@metamartis.com